Product Overview
The KR‑1310 bench‑top AC‑DC hipot (withstand voltage) tester is specialised electrical safety test equipment for wire, cable and insulated component evaluation. It can output both power‑frequency alternating‑current and direct‑current high‑voltage. By applying sustained high‑voltage stress to cable insulation layers, it detects insulation defects, potential breakdown risks and poor dielectric performance.
This compact unit supports adjustable breakdown trip‑current and configurable hold‑time for withstand‑voltage trials. Widely used within wire‑and‑cable factories, electrical component‑manufacturing workshops, quality‑control laboratories and third‑party electrical‑product‑verification institutes for routine production inspection and material‑performance validation.
Core Product Competitive Advantages
- Dual‑mode AC & DC high‑voltage output
One instrument delivers 0‑10 kV adjustable AC and DC high‑voltage outputs. Operators swiftly toggle between AC and DC test modes to satisfy different dielectric‑testing workflows for diverse cable‑insulation materials.
- Multi‑level selectable breakdown trip‑current
6‑grade breakdown‑current threshold options:0.5 mA, 1 mA, 3 mA, 5 mA, 10 mA, 20 mA. The equipment automatically cuts‑off high‑voltage output once specimen breakdown leakage‑current exceeds preset value, protecting both test sample and internal instrument circuits from damage.
- Programmable timed withstand‑voltage function
Test holding‑time adjustable from 1‑99 minutes. After starting the test, the unit maintains target high‑voltage automatically; it will stop output and trigger alarm when timing completes or breakdown event occurs, lowering manual‑operation workload for batch‑sample testing.
- Intuitive analogue‑meter read‑out & compact benchtop build
Clear analogue panel meters display real‑time voltage and leakage‑current variation. Front‑panel rotary knobs simplify voltage‑level and parameter setup. Portable metal‑enclosed cabinet occupies little bench‑top footprint, easy for lab‑station or production‑line deployment.
- Built‑in multi‑layer electrical‑safety safeguards
High‑voltage‑output warning marking, reliable grounding terminal and internal over‑current‑protection circuit reduce operator‑exposure‑risks during high‑voltage‑testing procedures, complying with basic lab‑high‑voltage‑operation‑safety‑requirements.
Complete Technical Parameter Table
| Parameter Item |
KR‑1310 Standard Specification |
| Input Power |
AC 220 V ±10 %, 50 / 60 Hz |
| AC Output Voltage |
0 ~ 10 kV continuously adjustable |
| DC Output Voltage |
0 ~ 10 kV continuously adjustable |
| Breakdown Trip‑Current |
0.5 mA / 1 mA / 3 mA / 5 mA / 10 mA / 20 mA selectable |
| Timed Withstand Test Range |
1 ~ 99 min adjustable |
Reference Test Standards: IEC 60243‑1, IEC 60811‑series cable insulation test norms
Standard Complete Test Operating Workflow
- Pre‑Test Preparation
Place tester on insulated stable work‑bench. Secure protective earth‑ground connection. Hook‑up mains‑power‑supply. Confirm high‑voltage output terminal is disconnected from sample. Select AC / DC working‑mode, set breakdown‑current gear and configure withstand holding‑time according to cable‑spec requirements.
- Specimen Connection
Switch‑off power supply before wiring. Connect test‑cable specimen between high‑voltage output terminal and ground return terminal. Double‑check wiring to prevent short‑circuit risk; keep operators away from high‑voltage exposed nodes during running phase.
- Start Withstand‑Voltage Test
Power‑on instrument, slowly ramp‑up output voltage to target‑value. Timing function activates automatically. Instrument keeps applying high‑voltage stress to cable‑insulation layer. Observe meter pointer for abnormal leakage‑current jump.
- Breakdown Judgement & Test Completion
If specimen insulation breaks down, leakage‑current exceeds threshold, the tester will immediately shut‑down high‑voltage and send alarm prompt. When pre‑set holding‑time expires without breakdown event, test passes. Manually lower output‑voltage down to zero.
- Post‑Test Tidying
Fully discharge capacitive‑type cable‑specimens. Disconnect test‑sample wiring. Power‑off main‑unit. Regularly inspect high‑voltage‑cable insulation condition and cabinet‑grounding‑reliability.
Wide Industrial Application Scenarios
Wire & Cable Manufacturing Enterprises
Batch withstand‑voltage QC inspection for power‑cable, signal‑cable and wiring‑harness products; screen insulation‑layer defects in finished‑goods and incoming‑material‑check links.
Electrical‑Component Production Factories
Dielectric‑strength verification for insulated sleeves, plastic‑insulated parts and wiring accessories.
R‑D Material‑Testing Laboratories
Evaluate dielectric‑breakdown‑resistance performance of new‑developed cable‑insulation‑compound materials.
University Electrical‑Engineering Laboratories
Teaching‑experiment‑instrument for high‑voltage‑dielectric‑performance‑research projects.
Third‑Party Accredited‑Electrical‑Testing‑Organizations
Carry‑out AC‑DC withstand‑voltage assessment for wire‑cable products for quality‑audit and certification‑related‑tasks.
Standard Factory‑Full‑Delivery Kit
- KR‑1310 AC‑DC hipot tester main benchtop unit
- High‑voltage test‑probe and ground‑return connecting‑cable set
- Power‑supply connecting‑cable
- Multilingual printed‑operation‑manual
- Factory‑issued performance‑inspection‑certificate
Optional spare‑parts & custom‑options: replacement high‑voltage‑test‑leads, custom‑power‑supply‑voltage‑adaptation.
Global Distributor & After‑Sales‑Support
We provide remote‑one‑on‑one operational guidance covering AC‑DC‑mode‑switching, breakdown‑current‑gear‑selection, specimen‑wiring and high‑voltage‑operation‑safety‑notes. Spare‑parts stock includes high‑voltage‑test‑cable accessories. Bulk‑order customers can apply for custom‑power‑supply‑voltage variants for overseas‑market deployment. Regional‑exclusive‑agent privileges contain priority‑production‑scheduling, OEM private‑branding‑services and complete‑set high‑definition product‑marketing‑image‑resources.
Product‑Banner‑Marketing‑Slogan
KR‑1310 Wire‑Cable AC‑DC Hipot Tester | 0‑10kV Dual‑Mode Withstand‑Voltage‑Tester For Cable‑Insulation‑QC‑Lab‑Production‑Line‑Testing
Core‑Feature‑Labels‑For‑Product‑Images
AC‑DC‑Dual‑High‑Voltage‑Output, 0‑10kV‑Adjustable‑Voltage, Six‑Gear‑Breakdown‑Trip‑Current, 1‑99Min‑Programmable‑Withstand‑Timer, Analogue‑Meter‑Real‑Time‑Readout, Benchtop‑Compact‑Cabinet, Over‑Current‑‑Protection, Wire‑Cable‑Insulation‑Dielectric‑Strength‑Evaluation, IEC60243‑1‑Compliant, Electrical‑Safety‑Production‑Line‑QC‑Instrument
Safety‑Operation‑Reminder
Strictly complete reliable protective‑grounding before power‑on. Do not touch high‑voltage‑terminals and specimen‑wiring while test‑running. Discharge capacitive cable‑samples thoroughly after finishing test‑run. Operators must comply with high‑voltage‑lab‑safety‑specifications.