KR‑2517 Mask BFE Tester

Additional information

ASTM F 2100 Medical Face Mask Materials Bacterial Filtration Efficiency %(BFE) Tester

Product Details:

Product Overview

The KR‑2517 bacterial filtration efficiency tester is dedicated lab‑grade equipment for evaluating bacterial barrier performance of medical‑grade mask materials. It generates standardized microbial aerosol challenge, passes the bacterial‑laden mist across mask specimens, and calculates BFE value by comparing upstream and downstream bacterial colony countsASTM Inter….

The unit integrates bio‑aerosol generator, aerosol mixing chamber, negative‑pressure biosafety cabinet and dual‑channel six‑stage Anderson cascade samplers. The whole test sequence runs under microcomputer automation. This instrument meets YY 0469‑2011, ASTM F2100, ASTM F2101 and EN 14683 test clauses. It is widely deployed in medical‑mask manufacturers, medical‑device inspection agencies, material‑research institutes and accredited third‑party PPE‑testing laboratoriessalesxhins….

Core Product Competitive Advantages

  1. Negative‑pressure enclosed biosafety cabinet design Full negative‑pressure containment prevents microbial aerosol leakage during testing, protecting lab personnel from bio‑hazard exposure. Transparent front glass door allows real‑time visual observation of internal test progress without opening the cabinet. Internal illumination facilitates sample‑setup inspection.
  2. Dual‑channel six‑stage Anderson cascade sampling system A‑B dual independent sampling paths are fitted inside the cabinet. The built‑in adjustable‑speed peristaltic pump precisely controls bacterial‑liquid atomization flow. Each sampling channel maintains standard 28.3 L/min sampling flow rate for accurate graded particle collection.
  3. Precision‑controlled microbial aerosol generation module Mass‑flow‑regulated aerosol nebuliser delivers stable bacterial‑mist output. It produces target median aerosol particle size of 3.0 ± 0.3 μm with geometric standard deviation ≤1.5, fully matching international BFE test‑particle‑size requirements.
  4. Industrial touch‑screen intelligent control & USB data export High‑brightness colour touch‑screen manages all parameter configuration, real‑time status monitoring and process logging. USB flash‑disk data‑dump function saves full‑run test datasets for later report compilation and lab‑archiving purposes.
  5. Complete multi‑layer electrical safety protection Equipped with built‑in electric‑leakage protection circuit, emergency‑stop button and over‑pressure safeguard. Oil‑free vacuum pump with silencer unit ensures low‑noise stable airflow, improving long‑duration lab‑testing comfort. Mobile lockable casters support convenient on‑site repositioning.

Complete Technical Parameter Table

Parameter Item KR‑2517 Standard Specification
Vacuum Pump Oil‑free rotary‑vane vacuum pump, max flow 57 LPM with silencer
Aerosol Generator Control Mass‑flow precise regulation
Sampling Channel Flow Dual‑channel 28.3 L/min; resolution 0.1 L/min
Peristaltic Pump Flow Range 0.01‑3.0 mL/min
Aerosol Particle Spec Median diameter 3.0±0.3 μm; GSD ≤1.5
Anderson Sampler Grade 6‑stage dual‑channel cascade impactor
Cabinet Negative‑Pressure 0‑120 Pa adjustable
Aerosol Chamber Dimension 600 × 80 × 5 mm
Working Ambient Temp 0‑50 ℃
Data Export USB U‑disk storage
Overall Dimension(L×W×H) 1200 × 650 × 2100 mm
Complete‑Machine Net‑Weight 120 KG
Rated Power Consumption <1500 W
Operating Noise <65 dB(A)

Compliance Standards: YY 0469‑2011, ASTM F2100, ASTM F2101, EN 14683

Standard Complete Test Operating Workflow

  1. Pre‑Test Preparation Position main unit on level lab ground and lock casters. Complete power‑supply connection. Prepare bacterial suspension liquid, agar culture plates and mask test‑specimens. Set aerosol‑flow, peristaltic‑pump rate and sampling‑time parameters via touch‑screen. Check negative‑pressure cabinet sealing status.
  2. Specimen & Sampler Setup Mount mask‑material specimen onto sample‑clamping fixture inside the negative‑pressure chamber. Install six‑stage Anderson samplers with prepared agar plates for upstream‑downstream bacterial collection. Close and latch the front glass cabinet door.
  3. Launch Automated BFE Test Start test program. Microbial aerosol generator produces standardized bacterial mist. Aerosol flows through aerosol mixing chamber and passes across test‑specimen. Dual‑channel samplers collect bacterial particles on agar plates under regulated sampling‑flow. Whole‑process negative‑pressure containment stays active.
  4. Post‑Sampling Plate Retrieval When preset sampling duration completes, aerosol generation and vacuum‑sampling stop automatically. Release cabinet negative‑pressure safely. Take out Anderson samplers and retrieve agar plates for subsequent constant‑temperature incubation and colony‑counting work. Calculate final bacterial‑filtration‑efficiency value according to colony‑count results.
  5. Post‑Test Tidying Clean aerosol pipeline and cabinet interior to eliminate residual bacterial‑liquid contamination. Power‑off instrument. Conduct regular maintenance for nebuliser, peristaltic‑pump and vacuum‑pump components.

Wide Industrial Application Scenarios

Medical‑Mask Manufacturing Enterprises

BFE batch‑quality‑control testing for surgical‑mask and disposable medical‑mask raw‑material; validate barrier‑property during new‑product‑material‑formula development.

Medical‑Device R‑D & Quality‑Control Departments

Evaluate bacterial‑blocking performance of non‑woven filter‑media, optimise multi‑layer composite‑material assembly solutions.

Medical‑Product Inspection & Metrology Institutes

Carry‑out standard‑compliant BFE verification for medical‑protective‑mask product‑release audits.

University Material‑Science & Biomedical Laboratories

Experimental‑research‑platform for biological‑aerosol filtration‑performance research.

Third‑Party Accredited‑PPE‑Testing‑Organizations

Conduct YY‑ASTM‑EN‑compliant bacterial‑filtration‑efficiency assessment and generate formal inspection‑documents for product‑certification‑audits.

Standard Factory‑Full‑Delivery Kit

  1. KR‑2517 mask bacterial‑filtration‑efficiency tester main cabinet unit
  2. Dual‑channel six‑stage Anderson cascade sampler assembly
  3. Microbial aerosol‑generation system & glass aerosol mixing chamber
  4. Oil‑free silent vacuum‑pump set
  5. Industrial colour touch‑screen control system with USB‑data‑export function
  6. Power‑supply connecting‑cable
  7. Multilingual printed‑operation‑manual complying with YY 0469‑2011, ASTM F2100, ASTM F2101, EN 14683‑specifications
  8. Factory‑issued performance‑inspection‑certificate

Optional spare‑parts & custom‑options: replacement peristaltic‑pump tubing, spare Anderson‑sampler parts, custom‑voltage power‑supply‑adaptation.

Global Distributor & After‑Sales‑Support

We provide remote‑one‑on‑one operational guidance covering parameter configuration, specimen‑mounting, aerosol‑system maintenance and daily equipment‑inspection routines. Spare‑parts stock includes pump‑tubing, sampler‑accessories and sensor‑spare‑parts. Bulk‑order customers can apply for custom‑power‑supply‑voltage variants for overseas‑market deployment. Regional‑exclusive‑agent privileges contain priority‑production‑scheduling, OEM private‑branding‑services and complete‑set high‑definition product‑marketing‑image‑resources.

Product‑Banner‑Marketing‑Slogan

KR‑2517 Mask BFE Tester | YY0469‑ASTM‑F2100‑EN14683‑Compliant Medical‑Mask‑Bacterial‑Filtration‑Efficiency‑Lab‑QC‑Certification‑Instrument

Core‑Feature‑Labels‑For‑Product‑Images

YY0469‑ASTM‑F2100‑EN14683‑Compliant, BFE‑Bacterial‑Filtration‑Efficiency‑Test, Negative‑Pressure‑Biosafety‑Cabinet, Dual‑Channel‑Six‑Stage‑Anderson‑Sampler, Mass‑Flow‑Aerosol‑Generator, 0.01‑3.0mL/min‑Peristaltic‑Pump, 28.3L/min‑Standard‑Sampling‑Flow, Color‑Touch‑Screen‑Control, USB‑U‑Disk‑Data‑Export, Oil‑Free‑Silent‑Vacuum‑Pump, Emergency‑Stop‑&‑Leakage‑Protection, Mobile‑Lockable‑Caster‑Base, Medical‑Mask‑Material‑Bacterial‑Barrier‑Performance‑Evaluation

Safety‑Operation‑Reminder

Strictly follow microbiological‑lab biosafety protocols during bacterial‑aerosol testing. Confirm cabinet negative‑pressure function works properly before starting each test‑run. Do not open front glass‑door while aerosol‑system is active. Regularly clean aerosol pipelines to prevent bacterial residue accumulation. Ensure reliable equipment‑grounding before power‑on.

Build Your Market with DGKAREY

KAREY products are trusted by customers across more than 100 countries, supporting long-term business growth in the testing equipment industry.
We are now seeking reliable partners to represent our brand in their local markets.

As an authorized distributor, you will receive dedicated regional support, ensuring a stable and protected business environment.
Your orders will be handled with priority, and our team will assist you with tailored equipment solutions based on your market needs.

From initial cooperation to ongoing development, we work closely with you to strengthen your presence and competitiveness.

DGKAREY – Your Reliable Partner in Global Supply

We go beyond supplying testing equipment. Our team manages the full journey — from export procedures to delivery at your door — ensuring efficiency, transparency, and peace of mind.

KR‑2517 Mask BFE Tester

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email sales@dgkarey.com

Get In Touch

Fill in the form below and our team will be happy to assist you

Contact Information

+86 769 2288 2009 
sales1@dgkarey.com

Opening Hours

Monday – Friday 9am-5pm 
Weekend – Closed

Address

Wentang, DongCheng District 523000, Dongguan City, Guangdong Province, PR China