KR-710 UL94 Horizontal & Vertical Integrated Flammability Test Chamber

RT-710 Flammability Combustion Test Chamber, Flame Retardant Test Equipment

This machine mainly used for plastic, rubber or film directly measured without burning combustion properties of plastics in the prescribed fire.

 

Product Details:

Product Introduction

The KR-710 all-in-one combustion testing cabinet is a standardized fire grading instrument built for polymer flame retardancy assessment. It adopts a calibrated Bunsen burner as the controlled ignition source, supporting horizontal HB test and vertical V0/V1/V2 dual test modes in a single unit. By monitoring burning speed, after-flame duration, glowing time and molten drip ignition risk under sealed windless environment, the equipment judges material UL94 fire resistance rating, which is mandatory safety inspection for electronic plastic parts, household appliance shells and automotive insulating materials.
This machine fully complies with UL94, IEC60695-11-3/11-4, GB/T5169 and multiple global fire test specifications, equipped PLC touch intelligent control and full safety interlock protection. It is widely used in electrical manufacturing factories, modified plastic R&D workshops, automotive material labs and CNAS third-party certification institutions for batch incoming inspection and new flame retardant formula screening.

UL94 Plastic Flammability Combustion Test Chamber

Core Competitive Advantages

  1. Dual Test Mode Quick Switch Design
    Two sets of interchangeable specimen fixtures are pre-installed inside the cabinet; operators only adjust burner angle and sample bracket position to rapidly switch horizontal and vertical testing without extra disassembly. Two dedicated burner configurations are matched separately: Model A for 20mm low flame (HB vertical test) and Model B for 40mm high flame (heavy-duty vertical grading), fully covering all UL94 standard flame height requirements.
  2. Precise Constant Gas Flow Control System
    High-precision gas flowmeter with ±1% regulation accuracy, fixed standard flow 105ml/min for low flame and 965ml/min for high flame. The burner base adopts motorized front-back alignment structure, jog adjustment to change the distance between flame and specimen, ensuring consistent ignition distance for each parallel test and eliminating manual positioning error. Methane/coal gas dual gas compatibility reduces user gas procurement restrictions.
  3. Full Set Intelligent Timing & Printing Control
    7-inch color touch screen paired with PLC core controller, three independent timing channels for ignition duration, residual flame time and afterglow time, adjustable range 0~999.9s with 0.1s resolution. Built-in thermal printer supports one-click output of complete test data curves and grade judgment records, realizing traceable laboratory inspection archives without additional computer connection.
  4. Multi-Layer Safety Protection Mechanism
    High-sensitivity gas leakage alarm sensor is installed in the cabinet interior; once fuel gas leakage is detected, the system automatically cuts off gas supply and triggers sound-light warning. The fully enclosed transparent observation door has safety interlock: the burner will stop igniting immediately if the cabinet door is opened during testing. Independent exhaust fan automatically discharges toxic combustion fumes after each cycle to protect lab staff from harmful smoke inhalation.
  5. Multi-Angle Adjustable Standard Burner
    The Bunsen burner with standard 9.5mm inner diameter and 100mm effective length supports 20°/45°/90° three angle switching, fully matching all test angle rules of international standards. The flame height can be continuously adjusted from 20mm to 175mm to adapt special high-flame testing schemes for high-strength composite materials.
  6. Large Closed Windless Test Chamber
    0.5 cubic meter sealed observation cavity isolates external air flow interference, avoiding flame deflection that distorts burning time data. Large tempered glass observation window provides full visual field for operators to record dripping and self-extinguishing phenomena without opening the cabinet door during testing. The whole machine adopts compact vertical layout, easy to place in standard laboratory countertops.

Complete Technical Parameter Table

Parameter Item KR-710 Unified Standard Index
Applicable Standards UL94, IEC60695-11-3/11-4, GB/T5169, UL1581/UL13
Standard Burner Spec Inner Φ9.5mm, total length 100mm with air balance holes
Adjustable Flame Height 20 ~ 175mm (Model A fixed 20±1mm; Model B fixed 40±2mm)
Standard Gas Flow Low flame:105±10ml/min; High flame:965±30ml/min, precision ±1%
Burner Adjustment Motorized front-back jog displacement, 20°/45°/90° multi-angle switch
Timing Range Ignition/after-flame/afterglow timer: 0~999.9s, resolution 0.1s
Test Chamber Volume ≥0.5m³ sealed windless cavity with transparent observation door
Fuel Gas Requirement ≥98% purity methane or industrial coal gas
Control System PLC + 7-inch touch screen + built-in thermal printer
Safety Configuration Gas leakage alarm, cabinet door interlock, automatic exhaust fan
Input Power AC220V 50Hz, standard single-phase power supply

Standard Complete Test Operating Flow

  1. Pre-Equipment Safety Inspection
    Connect qualified fuel gas pipeline, check gas tightness and leakage alarm function; power on the touch control panel and pre-check exhaust fan and timing module running status.
  2. Test Mode & Parameter Setup
    Select horizontal HB or vertical V-grade test program on the screen, set standard ignition time according material specification, adjust gas flow to reach standard flame height and stabilize for 30 seconds.
  3. Specimen Fixed Clamping
    Cut raw material into standard test strips, mount on corresponding horizontal/vertical fixture, adjust burner distance and angle to meet standard ignition position.
  4. Controlled Flame Ignition Test
    Activate the ignition program, the standard flame contacts the specimen surface for set duration then automatically retract; the system synchronously records self-extinguishing time, glowing duration and dripping ignition condition.
  5. Flame Retardant Grade Judgement
    After single specimen testing, repeat parallel sample experiments following standard staircase rules; the software automatically judges UL94 HB/V0/V1/V2 grade based on collected timing data, supports real-time curve display.
  6. Exhaust & Post-Test Cleaning
    Start automatic exhaust system to clear combustion smoke, cool the cabinet down completely, wipe soot residues on the burner and observation window for next batch testing.

UL94 Plastic Flammability Combustion Test Chamber

Wide Industrial Application Scenarios

Household Appliance Manufacturing

Refrigerator, air conditioner, small household electrical plastic shells, socket insulating bases; mandatory UL94 fire grade testing for product safety certification.

Lighting & Low-Voltage Electrical Factories

LED lamp housings, switch plastic parts, wiring terminal insulation pieces; evaluate flame spread risk under short-circuit high temperature environment.

Automotive New Material Labs

Automotive interior plastic panels, battery pack insulating shells, wire sheath materials; screen low-flammability modified composite formulas for new energy vehicles.

Plastic & Masterbatch Enterprises

Flame retardant PP, ABS, PC glass fiber reinforced engineering plastics, foam packaging materials; compare anti-combustion performance of different additive proportions.

Third-Party Fire Safety Certification Institutions

Carry out standardized compliance testing per international standards, issue authoritative inspection reports for product export, factory delivery and engineering access acceptance.

Standard Factory Full Delivery Kit

  1. KR-710 integrated flammability test main cabinet with automatic exhaust system
  2. Standard multi-angle adjustable Bunsen burner assembly (A/B dual flame accessories included)
  3. Horizontal + vertical dual groups of specimen clamping fixtures
  4. Gas flow control valve, pressure gauge and complete fuel connecting pipeline
  5. PLC touch intelligent control panel with built-in thermal printing module
  6. Gas leakage detection alarm and cabinet safety interlock assembly
  7. Full set of specimen cutting auxiliary tools and cabinet cleaning accessories
  8. Multilingual operation manual matching UL/ISO/GB fire test standards
  9. Factory flame flow and timing calibration inspection certificate

 

UL94 Plastic Flammability Combustion Test Chamber

Global Distributor & After-Sales Support

We provide one-on-one remote operation training and UL94 standard test parameter guidance, with long-term stable supply of spare burners, gas sensors and printer paper rolls. Custom 60Hz overseas power conversion versions and high-flame 5VA upgraded kits are available for bulk orders. Exclusive regional agent policies include priority production scheduling, OEM private brand customization and full sets of HD product marketing image resources.

English Image Overlay Text

Main Banner Title: KR-710 UL94 Horizontal Vertical Flammability Test Chamber

Control Panel Tags: TEST MODE / FLAME HEIGHT / TIMER SET / DATA PRINT / GAS ALARM

Feature Overlay Tags: HB/V Dual Modes / Gas Leak Protection / Touch PLC Control / Sealed Windless Chamber / Auto Exhaust Fan

Safety Operation Tip: Turn Off Gas Valve Before Opening Test Cabinet Door

Build Your Market with DGKAREY

KAREY products are trusted by customers across more than 100 countries, supporting long-term business growth in the testing equipment industry.
We are now seeking reliable partners to represent our brand in their local markets.

As an authorized distributor, you will receive dedicated regional support, ensuring a stable and protected business environment.
Your orders will be handled with priority, and our team will assist you with tailored equipment solutions based on your market needs.

From initial cooperation to ongoing development, we work closely with you to strengthen your presence and competitiveness.

DGKAREY – Your Reliable Partner in Global Supply

We go beyond supplying testing equipment. Our team manages the full journey — from export procedures to delivery at your door — ensuring efficiency, transparency, and peace of mind.

KR-710 UL94 Horizontal & Vertical Integrated Flammability Test Chamber

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email sales@dgkarey.com

Get In Touch

Fill in the form below and our team will be happy to assist you

Contact Information

+86 769 2288 2009 
sales1@dgkarey.com

Opening Hours

Monday – Friday 9am-5pm 
Weekend – Closed

Address

Wentang, DongCheng District 523000, Dongguan City, Guangdong Province, PR China